LC parallel tank filter
时间:03-30
整理:3721RD
点击:
Hi to all
Is it possible to block 20V AC signal
with L-C parallel tank filter around 15 MHz
or should i have some of them,
BR
Arye Nudelman
Is it possible to block 20V AC signal
with L-C parallel tank filter around 15 MHz
or should i have some of them,
BR
Arye Nudelman
Can you give us some more details; source output impedance, load impedance, intended frequency range, required attenuation, etc?
i'm measuring w Network analyzer from some 50 Ohm chip output to some load with a matching system between, in 15-20 Mhz freq
sometimes i'm connecting in parallel to the load some impedance and it seems like this new parallel impedance talking the energy,
so what i wish is to connect some filtering block in the ports of the new paralle to load impedance
that in those freqs the new impedance will be like an open circuit .
is it possible w using LC tank?
Thanks
Arye