关于power signoff 中的dynamic IR drop
时间:10-02
整理:3721RD
点击:
用PrimeRail做dynamic IR drop的分析时,报告中有这么一段话,Power domain VSS network voltage report
PEAK transient voltage:
Min voltage rise (mV) = 0
Max voltage rise (mV) = 2.405e3
Min voltage drop (mV) = 0
Max voltage drop (mV) = 799.54e-3
AVG transient voltage:
Min voltage rise (mV) = 0
Max voltage rise (mV) = 25.658
Power domain VDD network voltage report
PEAK transient voltage:
Min voltage rise (mV) = 0
Max voltage rise (mV) = 692.877e-3
Min voltage drop (mV) = 0
Max voltage drop (mV) = 2.315e3
AVG transient voltage:
Min voltage drop (mV) = 0
Max voltage drop (mV) = 32.553
需要关注的是PEAK transient voltage还是AVG transient voltage,这两个值哪个是我们所说的dynamic IR drop呢
PEAK transient voltage:
Min voltage rise (mV) = 0
Max voltage rise (mV) = 2.405e3
Min voltage drop (mV) = 0
Max voltage drop (mV) = 799.54e-3
AVG transient voltage:
Min voltage rise (mV) = 0
Max voltage rise (mV) = 25.658
Power domain VDD network voltage report
PEAK transient voltage:
Min voltage rise (mV) = 0
Max voltage rise (mV) = 692.877e-3
Min voltage drop (mV) = 0
Max voltage drop (mV) = 2.315e3
AVG transient voltage:
Min voltage drop (mV) = 0
Max voltage drop (mV) = 32.553
需要关注的是PEAK transient voltage还是AVG transient voltage,这两个值哪个是我们所说的dynamic IR drop呢
小编,请教一下,在用primerail分析IR-drop的时候,需要改wire的类型吗?
因为我在分析的时候,如果不改wire的类型的话,会导致用primerail打开设计,wire的属性丢失,最终导致提取寄生失败。
用的后端软件是ICC。
不太清楚你说的修改wire属性是什么意思,是change_name吗
wire的属性分别为wire/path/rectangle/polygon。我需要要将全部wire属性类型改成path才可以。
我的没有修改这些属性,可能是版本的问题吧
已经确认过了,需要关注的是avg的值
thank you for the confirmation
avg 在power analysis中代表static IR,这里代表的一定时间内power drop的平均值,一般要求3%左右
peak 在power analysis中代表dynamic IR,这是代表一定时间内峰值电流对应的IR,一般要求10%左右