大家好!

我跑hspice仿真,用MEASURE命令求解某点V2的最大值,给定了范围,但是碰到的“warning”:maxv2 **warning** exceeds analysis range ,请问这个warning怎么理解,本来一般不理睬warning的,但是这次没有结果是让人很觉得头疼的事情,求大侠指点迷津!

不胜感谢!

COMMANDS:
.MEASURE DC U_zero_3 Find V(V1) when V(V1) =V(V2)
.MEASURE DC U_zero_4 when V(V1) =V(V2) RISE=1
.MEASURE DC U_zero_5 when V(V1) =V(V2) FALL=1
.MEASURE DC U_zero_6 when V(V1) =V(V2) RISE=2
.MEASURE DC MAXVD MAX V(VD)
.MEASURE DC MAXV2 MAX V(V2) from=U_zero_5 to=UH

RESULTS:
u_zero_3= 6.3477E-01
u_zero_4= -6.3461E-01
u_zero_5= 4.3109E-02
u_zero_6= 6.3233E-01
maxvd= 3.3919E-01 at= -3.1640E-01
from= -6.3640E-01 to= 6.3360E-01
maxv2 **warning** exceeds analysis range
maxv2= failed from= 4.3109E-02 to= 6.3640E-01

我也遇到同样的问题。