微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > PCB设计问答 > Cadence Allegro > 请教:Import Logic 报错

请教:Import Logic 报错

时间:10-02 整理:3721RD 点击:
Import Logic  报错  什么问题?
#1   WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'BLANK' for device '2N6802_1_BLANK_SI2302DS_35-3390' not found in PSMPATH or must be "dbdoctor"ed.

库里面是不是没有这个封装

已解决   谢谢

没有psm文件 或者psm文件路径不对

dra psm pad 这一般的文件都需要有的。

库里面是不是没有这个封装

没封装哇

是警告,不是报错

#1   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0402_CIR' used by RefDes R1151 for device 'RES_0402_200_0.063W_1%_SMD_V__1' not found in PSMPATH or must be "dbdoctor"ed.
#2   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
——-————————
WARNING(SPMHNI-194): Symbol 'R0402_CIR' used by RefDes R1167 for device 'RES_0402_200_0.063W_1%_SMD_V__2' not found in PSMPATH or must be "dbdoctor"ed.
#23  WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol '0402_CIR' used by RefDes C1287 for device 'CAP_0402_0.1UF_16V_C0402_0.1UF_' not found in PSMPATH or must be "dbdoctor"ed.
#24  WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol '0402_CIR' used by RefDes C151 for device 'CAP_0402_0.01UF_16V_C0402_NI_10' not found in PSMPATH or must be "dbdoctor"ed.
#25  WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0402_CIR' used by RefDes R1149 for device 'RES_0402_200_0.063W_1%_SMD_V_R0' not found in PSMPATH or must be "dbdoctor"ed.
问一下,我所有0402的封装都有的。其他的0402阻容可以导入。仅上面25个。能导入,但是报错。

#1   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0402_CIR' used by RefDes RX151 for device 'RES_0402_200_0.063W_1%_SMD_V__1' not found in PSMPATH or must be "dbdoctor"ed.
#2   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
——-————————
WARNING(SPMHNI-194): Symbol 'R0402_CIR' used by RefDes RX167 for device 'RES_0402_200_0.063W_1%_SMD_V__2' not found in PSMPATH or must be "dbdoctor"ed.
#23  WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol '0402_CIR' used by RefDes CX287 for device 'CAP_0402_0.1UF_16V_C0402_0.1UF_' not found in PSMPATH or must be "dbdoctor"ed.
#24  WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol '0402_CIR' used by RefDes CX51 for device 'CAP_0402_0.01UF_16V_C0402_NI_10' not found in PSMPATH or must be "dbdoctor"ed.
#25  WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0402_CIR' used by RefDes RX149 for device 'RES_0402_200_0.063W_1%_SMD_V_R0' not found in PSMPATH or must be "dbdoctor"ed.

应该是封装库中缺少R0402_CIR和0402_CIR两个封装的psm文件,注意,文件名要完全一样