Impedance Inverters (K) or Admittance Inveters (J)
时间:04-10
整理:3721RD
点击:
In designing filter, normally we will have couplings such as Impedance Inverters (K) or Admittance Inveters (J). How to realise these Ks or Js in practical? Thank you
You can realize J or K inverters using capacitive gaps or coupled lines or simply lampda/4 T.Ls .
For more information please refer to Microwave Engineering 2nd edition chapter 8,pages 469 474-485 490-493 .
Dear ieropsaltic, thanks for the advice. Since i am going to realise my design into co-axial resonator filter, is it i'm able using the same method as per mentioned by Pozar? Do you have any info regarding coaxial resonator filter design? thks again