What does terminate a signal pin with 50 ohm mean?
时间:04-09
整理:3721RD
点击:
Hi ,
What does terminate a signal pin with 50 ohm mean? Does it mean tying the pin to GND through a 50 ohm resistor?
thanks for taking the time to respond.
What does terminate a signal pin with 50 ohm mean? Does it mean tying the pin to GND through a 50 ohm resistor?
thanks for taking the time to respond.
Yes, in principle what you say is ok.
In general 50 ohms is referring to a load which is pure resistive.
hi EE-2002,
most RF circuits are designed to match at 50 ohm. So when you terminate a signal line with 50 ohm load, you are making the end of the signal line matched. Thus when there is a signal reaching the end of the line, it will get absorbed and not reflected back to the input.
check out the attachment in https://www.edaboard.com/viewtopic.php?p=903307#903307
i've posted the reason...