Help LM741 ground connection, what is it?
Thanks.
The - terminal is the ground of OpAmp. You should make good connections between the - terminal and the OpAmp Ground using ground plane.
The 741 needs a +- power supply so its earth pin needs to be about halfway between the + and - power lines. In your case get two equal value resistors connect one end of each one to your + and - battery terminals and call the centre connection of the resistors "earth". 741s normally need more then +-4.5 Volts to make them work properly, look at their data sheet.
Frank
don't waste your time. lm741 does not have a prayer of working at 25 MHz
Agreed ... you want something like a OP27 series (40MHz bandwidth) or something like a LT1007 series (60MHz bandwidth)
Dave