微波EDA网,见证研发工程师的成长! 2025婵犵數濮撮惀澶愬级鎼存挸浜炬俊銈勭劍閸欏繘鏌i幋锝嗩棄缁炬儳娼¢弻鐔告綇閸撗呮殸缂備胶濯崹鍫曞蓟閵娾晜鍋嗛柛灞剧☉椤忥拷04闂傚倸鍊搁崐鎼佸磹妞嬪海鐭嗗〒姘e亾妤犵偞鐗犻、鏇㈡晜閽樺缃曢梻浣虹帛閸旀洟骞栭銈囦笉妞ゆ牜鍋為悡銉╂煟閺囩偛鈧湱鈧熬鎷�11闂傚倸鍊搁崐鎼佸磹妞嬪海鐭嗗〒姘e亾妤犵偞鐗犻、鏇㈡晝閳ь剛绮eΔ浣虹闁瑰瓨鐟ラ悘鈺冪磼閻欌偓閸ㄥ爼寮婚妸鈺傚亞闁稿本绋戦锟� 闂傚倸鍊搁崐鎼佸磹妞嬪海鐭嗗〒姘e亾妤犵偞鐗犻、鏇㈠Χ閸屾矮澹曞┑顔结缚閸樠冣枍瀹ュ洠鍋撶憴鍕;闁告濞婇悰顕€宕堕澶嬫櫌婵犵數濮撮幊澶愬磻閹捐閿ゆ俊銈勮兌閸欏棝姊虹紒妯荤闁稿﹤婀遍埀顒佺啲閹凤拷濠电姷鏁告慨鐑藉极閹间礁纾绘繛鎴欏灪閸嬨倝鏌曟繛褍鍟悘濠囨⒑閹稿海绠撴い锔诲灣缁顢涢悙瀵稿弳闂佺粯娲栭崐鍦偓姘炬嫹
首页 > 研发问答 > 微波和射频技术 > 电磁仿真讨论 > Matching port in Agilent MOMENTUM

Matching port in Agilent MOMENTUM

时间:03-31 整理:3721RD 点击:
Hi all,

How to define, in Momentum, a port having impedance matching with the characteristic impedance of the linked network ?

I have to simulate a two ports network over a wide range of frequencies and I would like to close the output port on a matched impedance; anyway, when I define a port, I can indicate just a single value of impedance

Export layout in to schematic by component create look alike option.
Now use REf net design termination in schematic.

My problem is the following:

I have drawn a layout in Momentum: 2 square coils (in cond & cond2) with some substrates in between. Then I have defined 2 pairs of ports for the 2 coils: each pairs is realized using an internal port and a ground reference port.

Which value should I use for the impedance of the two internal ports ?
The default one is 50 Ohm

Now I would like to make a S-parameter calculation using Momentum: should I close the two pairs of ports on two impedances matching the characteristic impedance of the network ?

Thanks a lot for your precious help! :D

Problem is not understood by me.

Added after 50 seconds:

Some one please help him.

Hi,

I have had a long discussion with an Agilent expert and now I have the ideas a little more clear:

S-matrix depends only by the network and not by the source/load impedance.

Setting the input & output ports at 50 Ohms will return me a S-matrix normalized to 50 Ohms (S_50). Setting the input & output ports at 75 Ohms will return me a S-matrix normalized to 75 Ohms (S_75)... and so on...

I can pass from one to the other with some calculus and that all, I don't need to close my network on matched loads to run simulations.

I hope I have correctly understood!