微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 微波和射频技术 > 电磁仿真讨论 > Best way to simulate microstrip filter with EM shielding in CST?

Best way to simulate microstrip filter with EM shielding in CST?

时间:03-30 整理:3721RD 点击:
Hi everyone!

I have coupled microstrip filter, designed in Genesys. PCB i'm designing it for will be covered with EM shielding, and I have to simulate filter with shielding, to be sure it will work.

So the question is - can someone tell, what is the best way to import design from Genesys to CST, while saving each trace individuality, so I could later optimize filter in CST? I have CST 2010 Microwave, Microstrip and CST Design available.

I Had an idea, to redraw design in CST Design, and later import it in CST MS/MW, but I cant find any option of importing CST Design model into CST Microwave / Microstrip.

Thanks for help!
Tim

I am not sure whether Genesys can export PCB into other form, like ASCII, ODB++, etc?

CST MS do support variety of importing formats.

Got this problem resolved by simply redrawing topology to the CST by myself.

Still, you can test circuit made in genesys with CST trough export/import as gerber or dxf, but this method does not allow you to make any modifications, when structure is imported into CST.

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top