Question About HFSS Port Renormalizing
时间:03-30
整理:3721RD
点击:
I am currently running a simulation on a transmission line where i use two lumped ports:
Port 1 have an Impedance of 50 Ohm
Port 2 an Impedance of 10 kOhm - 132j Ohm
I am looking at the coupling between the two ports, in other words: S12
So should I run with both ports renormalized to get the correct S12 or not?
Thanks a lot,
Mads
Ps. I noticed that by default, lumped ports are renormalized to a 50 Ohm full port impedance, which means that the renormalization only really matter for port 2.
Port 1 have an Impedance of 50 Ohm
Port 2 an Impedance of 10 kOhm - 132j Ohm
I am looking at the coupling between the two ports, in other words: S12
So should I run with both ports renormalized to get the correct S12 or not?
Thanks a lot,
Mads
Ps. I noticed that by default, lumped ports are renormalized to a 50 Ohm full port impedance, which means that the renormalization only really matter for port 2.
This thread might help to answer some parts of your question: https://www.edaboard.com/thread196077.html