lumped elements
时间:03-25
整理:3721RD
点击:
Hallo,
when measuring interdigial capacitors or printed inductors, how important
is the microstrip line's width of the contacts.
If I can deembed the line in post processing it should be without influence.
But how much S11 reflection is allowed to get still enough measuring power on the
capacitor or inductor.
I think of
interdigital_caps with width=50um and gap=50um
inductors with width=50um, gap=50um
I would contact it to a microstrip line with width=50, 100, 150 um.
Thanks for any reply
when measuring interdigial capacitors or printed inductors, how important
is the microstrip line's width of the contacts.
If I can deembed the line in post processing it should be without influence.
But how much S11 reflection is allowed to get still enough measuring power on the
capacitor or inductor.
I think of
interdigital_caps with width=50um and gap=50um
inductors with width=50um, gap=50um
I would contact it to a microstrip line with width=50, 100, 150 um.
Thanks for any reply
Hi
I think it's fundamental question
The s-parameters are exact if we have established what trans line connected to component and in what substrate component is placed
The using s-parameters measured on one substrate with one width of trl to model component behavior with another trl width produce errror due to component-trl coupling. We can not remove this error using step in width component simple!
But i dont know exact rule how to hand calculate the value of this error.
You can study this with momentum simulator.
Regards