cyclone III限制的非全局控制信号
时间:10-02
整理:3721RD
点击:
对子模块编译出现
Error: Cell DatAMC[3]~reg0 fed by 5 non-global control signals -- only 4 control signals may be non-global
这个怎么解决啊
Its help says:
CAUSE: The specified cell is fed by the specified number of control signals that are non-global signals. However, the current target device only supports the specified number of non-global control signals.
ACTION: Assign the Global Signal option with a value of Global Clock to one of the clocks, or modify the design so that the cell is driven by less control signals such as clock or asynchronous clear.
怎么把时钟设成全局信号?
Error: Cell DatAMC[3]~reg0 fed by 5 non-global control signals -- only 4 control signals may be non-global
这个怎么解决啊
Its help says:
CAUSE: The specified cell is fed by the specified number of control signals that are non-global signals. However, the current target device only supports the specified number of non-global control signals.
ACTION: Assign the Global Signal option with a value of Global Clock to one of the clocks, or modify the design so that the cell is driven by less control signals such as clock or asynchronous clear.
怎么把时钟设成全局信号?
?
你这几个信号的扇出很大吗? assignment editor里面可以设置 或者用脚本语句 具体忘记了