出IPC的时候报以下错误,应该怎么弄
Warning: Found a mechanical pin at location (-34.7880 -7.6350) with no drill - skipping.
Warning: Found a mechanical pin at location (-34.7880 8.8750) with no drill - skipping.
Error: Integer value 10000 can not be written in columns 59-62  on line 1126.
Error: Integer value 10000 can not be written in columns 59-62  on line 1216.
Error: Integer value 10000 can not be written in columns 64-67  on line 1216.

------------------------------------------
SUMMARY:
  Errors:       3
  Warnings:     2
Info: Most likely cause of "Integer value" errors are:
      - (Most likely) Coordinates in the database exceed IPC's coordinate system.
        Try setting the database origin to center the design to reduce the large
        coordinate values.
      - Large pad sizes. Reduce any large pad sizes.

建議使用 IPC-356A 欄位長度比較沒問題

建議使用 IPC-356A 欄位長度比較沒問題

我是用的IPC-356A