微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > PCB设计问答 > Cadence Allegro > CAPTURE导不了网表 求高手指点原因

CAPTURE导不了网表 求高手指点原因

时间:10-02 整理:3721RD 点击:
如下错误如所示:
** Netlisting the design *********************************************************************************Design Name:E:\ALLEGOWORK\圆裕\TO-D06B\SCH\to-d06b.dsnNetlist Directory:E:\ALLEGOWORK\圆裕\TO-D06B\SCH\allegroConfiguration File:\Cadence\SPB_15.5.1\tools\capture\allegro.cfgSpawning... "D:\Cadence\SPB_15.5.1\tools\capture\pstswp.exe" -pst -d "E:\ALLEGOWORK\圆裕\TO-D06B\SCH\to-d06b.dsn" -n "E:\ALLEGOWORK\圆裕\TO-D06B\SCH\allegro" -c "D:\Cadence\SPB_15.5.1\tools\capture\allegro.cfg" -v 3 -j "CB Footprint"#1 Error   [ALG0065] Illegal character in \multi-tp control board(cf-19)\.#2 Aborting Netlisting... Please correct the above errors and retry.Exiting... "D:\Cadence\SPB_15.5.1\tools\capture\pstswp.exe" -pst -d "E:\ALLEGOWORK\圆裕\TO-D06B\SCH\to-d06b.dsn" -n "E:\ALLEGOWORK\圆裕\TO-D06B\SCH\allegro" -c "D:\Cadence\SPB_15.5.1\tools\capture\allegro.cfg" -v 3 -j "CB Footprint"*** Done ***

Allegro对中文的支持不是很好。最好不用中文名或路径。你可以试试。

還有一個問題提醒 , 不要把公司名稱給流出來 . 看你貼的資料 , 把客戶名稱都貼出來了 ,很不好.
萬一這家公司有人剛好在網路上看到 , 到時候真的追究起來 , 可能捲鋪蓋還算好的(很不巧我知道這家公司 ).

你不提醒可能还没人在意,你那么一说反倒是都刻意去找那个名字

遇到过某些情况是做symbol的时候,symbol名字中间带有非法字符而并非一定是中文路径的问题,当然,同样不推荐中文路径。

  谢谢!

   多谢兄台提醒

嗯嗯
看到这句没,错误所在1 Error   [ALG0065] Illegal character in \multi-tp control board(cf-19)
所以就是有非法字符,修改一下再试试

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top