一个比较白痴的问题。希望有人帮我
我画了一个原理图,后来在做用PCB editor生成PCB板时发现原理图有错误,然后我重新打开原理图用DRC检查,发现好多错误,有一些我已经纠正了,但是还有一部分错误我确不知道原因,如下:
Checking Electrical Rules
WARNING [DRC0007] Net has no driving source N07686: SCHEMATIC1, PAGE1 (3.50, 5.20)
Checking For Single Node Nets
WARNING [DRC0006] Net has fewer than two connections PA6: SCHEMATIC1, PAGE1 (8.80, 9.30)
WARNING [DRC0006] Net has fewer than two connections N18638: SCHEMATIC1, PAGE1 (9.80, 4.00)
WARNING [DRC0006] Net has fewer than two connections PC5: SCHEMATIC1, PAGE1 (14.30, 5.70)
WARNING [DRC0006] Net has fewer than two connections PC1: SCHEMATIC1, PAGE1 (10.20, 8.70)
WARNING [DRC0006] Net has fewer than two connections N07293: SCHEMATIC1, PAGE1 (1.50, 5.10)
WARNING [DRC0006] Net has fewer than two connections PA7: SCHEMATIC1, PAGE1 (10.20, 6.20)
WARNING [DRC0006] Net has fewer than two connections PD4/AREF: SCHEMATIC1, PAGE1 (14.30, 7.20)
WARNING [DRC0006] Net has fewer than two connections PA3: SCHEMATIC1, PAGE1 (8.80, 7.80)
WARNING [DRC0006] Net has fewer than two connections PC2: SCHEMATIC1, PAGE1 (10.20, 9.30)
WARNING [DRC0006] Net has fewer than two connections N09742: SCHEMATIC1, PAGE1 (2.90, 7.30)
WARNING [DRC0006] Net has fewer than two connections PB1: SCHEMATIC1, PAGE1 (10.20, 7.20)
WARNING [DRC0006] Net has fewer than two connections N07297: SCHEMATIC1, PAGE1 (1.50, 5.20)
WARNING [DRC0006] Net has fewer than two connections TDX: SCHEMATIC1, PAGE1 (11.80, 1.50)
WARNING [DRC0006] Net has fewer than two connections N07686: SCHEMATIC1, PAGE1 (3.50, 5.20)
WARNING [DRC0006] Net has fewer than two connections RF_SIGNAL: SCHEMATIC1, PAGE1 (12.60, 5.40)
WARNING [DRC0006] Net has fewer than two connections PD5/PWMOUT: SCHEMATIC1, PAGE1 (14.30, 7.80)
WARNING [DRC0006] Net has fewer than two connections PC6: SCHEMATIC1, PAGE1 (14.30, 6.20)
WARNING [DRC0006] Net has fewer than two connections PA4: SCHEMATIC1, PAGE1 (8.80, 8.30)
WARNING [DRC0006] Net has fewer than two connections RDX: SCHEMATIC1, PAGE1 (11.80, 1.70)
WARNING [DRC0006] Net has fewer than two connections PC3: SCHEMATIC1, PAGE1 (11.60, 8.30)
WARNING [DRC0006] Net has fewer than two connections PA1: SCHEMATIC1, PAGE1 (8.80, 6.70)
WARNING [DRC0006] Net has fewer than two connections LNA_ON_1: SCHEMATIC1, PAGE1 (7.60, 2.60)
WARNING [DRC0006] Net has fewer than two connections PB3: SCHEMATIC1, PAGE1 (10.20, 7.70)
WARNING [DRC0006] Net has fewer than two connections PA5: SCHEMATIC1, PAGE1 (8.80, 8.80)
WARNING [DRC0006] Net has fewer than two connections PC7: SCHEMATIC1, PAGE1 (14.30, 6.70)
WARNING [DRC0006] Net has fewer than two connections PC4: SCHEMATIC1, PAGE1 (11.60, 7.70)
WARNING [DRC0006] Net has fewer than two connections PC0: SCHEMATIC1, PAGE1 (10.20, 8.20)
WARNING [DRC0006] Net has fewer than two connections PB0: SCHEMATIC1, PAGE1 (10.20, 6.70)
WARNING [DRC0006] Net has fewer than two connections GND_POWER: SCHEMATIC1, PAGE1 (0.60, 2.00)
Checking For Unconnected Bus Nets
希望大虾们能帮帮我~~~~
我发现这个问题的原因了~~~就是这个工程是由多个板子构成的,另一个板子的原理图我没画出来,所以显示有的引脚悬空,我想问一下这样可以生成PCB板吗?我在PCB中导入网表时出现了如下错误:
Packager files not found
#2 ERROR(102) Run stopped because errors were detected
netrev run on Apr 22 11:37:44 2010
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
2 errors detected
No oversight detected
No warning detected
cpu time 0:00:26
elapsed time 0:00:01
这又是什么意思呢?
[DRC0007]的错误一定要注意,一般情况下是因为某个net孤立引起的,这种的要根据坐标仔细检查,很有可能是该net是单端连接,与其他的同一个net没有联接上造成的
[DRC0006]的错误有的可能是net没有联接上造成,也要仔细确认一下
谢谢啦!很有用,记下了!