微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 微波和射频技术 > 天线设计和射频技术 > For RKE application how to match the impedance

For RKE application how to match the impedance

时间:04-09 整理:3721RD 点击:
between the PCB antenna SAW filter and LNA, shall i use noise matching to match

SAW out and LNA input?

thank you for advance

Why is the SAW-filter located in front of the LNA? The insertion loss of the SAW-filter will degrade the noise figure of the LNA.