微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 微波和射频技术 > 天线设计和射频技术 > Re: Circuit Board is not working properly at 2.4GHz

Re: Circuit Board is not working properly at 2.4GHz

时间:04-04 整理:3721RD 点击:
Please show a photo or drawing of the PCB layout and clarify how the 500 ohm RF probe is connected to the circuit. Only "barrel" or short ground clip can reproduce 2.4 GHz correctly.

As far as I understand, you have the generator unterminated (please correct me if I'm wrong). This can be expected to cause some additional magnitude error due to non-perfect generator output matching, but unlike in a 7 dB order of magnitude.

Frank, that is very possible if he probes the location-dependent standing wave voltages on the unterminated line. That can be twice the 50 Ohm voltage (at open end and n*lambda/2 locations) or zero voltage (at 1/4 lambda + n*lambda/2 from open end).

I agree he needs to show a photo of the test setup, including probe connection.

That's of course possible if we have a line of sufficient length, not probed at the end. According to the (vague) description, I was expecting only short traces on the PCB.


Thank you sir,

"I was just trying to see the difference in result at 1.2 GHz and 2.5 GHz, without terminating. And able to see the 8 to 9 dB difference, so I was worried." Sorry for that.

So then please help me out to find the reason that Why my circuit is giving 8 - 9 dB extra loss at 2.5GHz.
I will share my circuit and layout.

Your
measurement
method
is
wrong.

Don't
trust
measurement
results.

Learn
to
do
correct
RF
measurements.

上一篇:180° hybrid phase balance
下一篇:最后一页

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top