measured negtive gain of a power amplifier
时间:04-08
整理:3721RD
点击:
Hey, guys. I have problems in using a 35GHz power amplifier---Triquent 4522. Its biasing are right, the max output power is 20dBm , but the gain is negtive.
Have you ever encountered this kind of weird measured results?
Thanks. Any advice will be appreciated.
Have you ever encountered this kind of weird measured results?
Thanks. Any advice will be appreciated.
Any advice?
The amplifier is dead..
I think..
Check the calibration/scale.
AS it is giving 20dBm power it may not dead completely.
Added after 1 hours 20 minutes:
I guess one path would have blown.
Check the current consumption on each path.
In balanced mode if one path fails then you will end in 6 dB loss.