Converting 2 port S parameter to 3 port S parameter
I know one can program all the required equations in ADS. But does ADS or any other tools have any built-in features that can handle this?
You can "lift" the ground connection of the ADS S2P component, so that you have 3 terminals, and connect it as needed.
That is what I thought too. Have you ever verified (or have ways to show) this approach is correct?
Yes, I have used that a lot.
Ok. So this approach gives you the results as you expected in your circuit simulations/designs.
Thank you.
Hi
See Chapter 12 (page 843) of the book " Foundations.for.Microwave.Engineering, by R.E.Collin, 2nd ed."
done! i try it, and it works.
Thanks for the input. I didn't notice Collin actually has these equations too. I first saw them in an Agilent app note.
---------- Post added at 08:26 ---------- Previous post was at 08:23 ----------
Got busy lately. Saw your reply. Really impressed by your imagination. Thanks 4 ur participation, dude.
Yap, man. You are very right. Thank you very much!