Periodic boundaries conditions in HFSS. Master/slave vs. PEC/PMC
时间:03-30
整理:3721RD
点击:
Hello,
Does anyone know the difference between different periodic boundary conditions in HFSS. What is the difference between linked boundary conditions (Master/Slave) and PEC/PMC boundary conditions.
Which one is better to use for simulating the unit cell of the antenna? Master/slave or the waveguide simulator (A waveguide with PEC walls) ?
Thanks,
Does anyone know the difference between different periodic boundary conditions in HFSS. What is the difference between linked boundary conditions (Master/Slave) and PEC/PMC boundary conditions.
Which one is better to use for simulating the unit cell of the antenna? Master/slave or the waveguide simulator (A waveguide with PEC walls) ?
Thanks,
Hi Ben,
If you have HFSS installed on your PC go to the C: drive --> Ansoft --> HFSS --> Help. Inside you'll find a pdf tutorial guide named "HFSSFloquet". I think this should cover your questions.
Also from another HFSS tutorial "HFSS Help_Antenna" there is some explanation in section 4 under "Boundary Conditions"
Hope this helps.
hi
Master/Slave boundary are used for periodic structures that go to infinity but pec/pmc are used for structures that are electric or magnetic conductors,
in fact if im right, you have to use Master/Slave boundary because your structure is periodic!
regards
red