Hi

I am trying to incorporate opa301 in a simulation. Downloaded the spice files from TI and converted them as THIS says. However the simulation return the error massage: "INTERNAL ERROR -- Divide by Zero, Divide" which means that some fundamental parameter is zero. taking a closer look at the model files I found out that all the .model files in the spice model are not addressed anywhere in the net-list and the model files created are bad as shown below:

Code:
X_U2.POUT            
PMOS                      
LEVEL    1               
L  100.000000E-06   
W  100.000000E-06  
VTO    -.7             
KP  200.000000E-06 
GAMMA    0                      
PHI     .6                     
LAMBDA    0               
IS   10.000000E-15  
JS    0                         
PB     .8                  
PBSW     .8                   
CJ    0                      
CJSW    0                      
CGSO    0               
CGDO    0                 
CGBO    0                         
TOX    0                       
XJ    0                    
UCRIT   10.000000E+03   
DIOMOD    1                         
VFB    0                    
LETA    0                        
WETA    0                      
U0    0                 
TEMP    0                   
VDD    5                      
XPART    0
Is this the reason I get that error ?
How or where can I access these .model files then ?