Hi! Everyone!

After I simulated, I want to remove higher mode from ports by Exclude port mode in Post Processing,then exported S parameters. But CST appeared message:

Export S parameters data failed.

My model is APC-7 coax air transmission line, and the middle part is Teflon.

What is the problem? Thanks.

I have following questions to understand your problem better
1. Which solver of CST you are using?
2.What S parameters data will be left when you say exclude port mode as per my understanding S parameters are calculated at ports. So when you exclude ports nothing is left to be exported so it is the error in post processing

I choice Frequency domain solver as solver.
Oh, I see! However I want to remove higher mode from ports so that S-parameters results don't include effect from my 2-ports measurement.
Is there other method to remove effects caused by ports?

Copyright © 2017-2020 微波EDA网 版权所有