CST MS : Parameter Sweep : Wrap Phase possible?
时间:03-26
整理:3721RD
点击:
Hi there,
does anybody know the same issue while performing parameter sweeps:
The phase information of an S parameter is always unwrapped and the WRAP tool does not work in my case, even if the results are very close.
For sure I could write a VBA script and search for the minimum phase
etc. but has anybody resolved this before ?
thx a lot,
radioC
does anybody know the same issue while performing parameter sweeps:
The phase information of an S parameter is always unwrapped and the WRAP tool does not work in my case, even if the results are very close.
For sure I could write a VBA script and search for the minimum phase
etc. but has anybody resolved this before ?
thx a lot,
radioC
that problem appear when you use parameters sweep but if you make simulation run after run(changing the variable manually) after every run ,you could wrap your phase
regards
Finally I hit on the following solution :
Copy the entire result of the parameter sweep into
a NEW FOLDER in the conventional S Parameter Result Folder
and CST will do the wrap up job automatically for you.