首页 > 研发问答 > 微波和射频技术 > 电磁仿真讨论 > HBM Model Simulation ESD - TINA TI

HBM Model Simulation ESD - TINA TI

时间:03-25 整理:3721RD 点击:
Hi
I am trying to understand the behaviour of Human Body Model simulation circuit in Tina TI.

I found a circuit provided by TI (as below)



I ran a transient analysis of this and got the curves as shown in the graph above (for Vout & AM1)

The way I understand is: that Human body side is modelled as 100pF Capacitor with some initial charge of 2kV. & it discharges through 1500 resistor.

What I am struggling to understand is that during this transient analysis how is this Switch SW1 behaving? (I can see the SW1 open but I still see the Current & voltage waveforms)

What is the purpose of L1 here?

Are C22 & R2 representing any random load?

I have done another transient analysis (this time probing Vin aswell)



So, it looks like Vin (Charge across 100pF) is decaying down with time but still don't know how!? In order for it to decay somehow the switch needs to connect it to the node of 'L1' but when and how is that happening?




Ok I think I found the answer to the question related to 'Switch'. It looks like SW1 is Time-Controlled Switch & it is set ti turn ON at t= 0sec & OFF at t= 1sec

So only help I need is the reason for L1 & if C2 & R2 are some random load?

Switch implementation is something that varies widely (if
it's even supported at all) in simulator dialects and symbol
libraries. You need to get tight with the specific simulator's
documentation.

But for an ESD "stinger" you can also use a vpulse stepping
from zero to Vhbm in appropriate risetime (1-10nS) instead
of the series vdc=Vhbm and switch (keep the resistor). The
simple series pulsed source, capacitor, resistor will throw
the same waveform.

I wonder why the circuit in post #1 differs from IEC 61000-4-2 generator specification with 150 pF charge storage and 330 ohm discharge resistor. The series inductor L1 is apparently there to model a finite rise time. 5 ns L/R time constant is relative large for typical contact discharge waveforms but may fit air discharge.

In the "random load" used in the setup, C2 is effectively useless according to the 20 ps time constant formed by it. A non-inductive resistive load like R2 is useful to measure the generated ESD current waveform, but doesn't model the typical ESD target impedance.