ICC complaining no physical cell descriptions
时间:10-02
整理:3721RD
点击:
loading tcbn28hpmbwp35hvtss0p81v125c_ecsm.db OK, but with warning:
Warning: The 'SEDFD2BWP35HVT' cell in the 'tcbn28hpmbwp35hvtss0p81v125c_ecsm' technology library does not
have corresponding physical cell description. (PSYN-024)
I knew tcbn28hpmbwp35hvtss0p81v125c_ecsm.db only have logic/timing/power info. for the standard cell, why ICC complaining the physical info.
I did have the following loaded OK for physical:
milkyway/tcbn28hpmbwp35hvt_120a/frame_only_HVH_0d5_0/tcbn28hpmbwp35hvt
Please help, Design is in, floorplan is in, though
Warning: The 'SEDFD2BWP35HVT' cell in the 'tcbn28hpmbwp35hvtss0p81v125c_ecsm' technology library does not
have corresponding physical cell description. (PSYN-024)
I knew tcbn28hpmbwp35hvtss0p81v125c_ecsm.db only have logic/timing/power info. for the standard cell, why ICC complaining the physical info.
I did have the following loaded OK for physical:
milkyway/tcbn28hpmbwp35hvt_120a/frame_only_HVH_0d5_0/tcbn28hpmbwp35hvt
Please help, Design is in, floorplan is in, though
写中文多好啊
这个warning一般发生在logic和physical信息不一致。比如说physical库中缺少SEDFD2BWP35HVT的CEL view。又或者logic中有三个端口,physical中却只有两个。
如果设计中没用到SEDFD2BWP35HVT,可以忽略这个warning。