微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 微电子和IC设计 > IC后端设计交流 > 请教:ASTRO中抽取扫描链信息的问题

请教:ASTRO中抽取扫描链信息的问题

时间:10-02 整理:3721RD 点击:
使用axgScanTrace抽取扫描链信息
;; axgScanTrace
#t
;; formDefault "Scan Trace"
#t
;; setFormField "Scan Trace" "Port Name" "C"
#t
;; setFormField "Scan Trace" "Of" "cell instance"
#t
;; setFormField "Scan Trace" "Instance Name" "PAD_CHIP/PAD_SI1"
#t
;; setFormField "Scan Trace" "Specify Chain End" "1"
;; setFormField "Scan Trace" "End Port Name" "I"
;; setFormField "Scan Trace" "Of 2" "cell instance"
;; setFormField "Scan Trace" "End Instance Name" "PAD_CHIP/PAD_SO1"
;; setFormField "Scan Trace" "Allow Buffers" "1"
;; setFormField "Scan Trace" "Buffer Master Name(s)" ".*INV.*,.*BUF.*"
;; formApply "Scan Trace"
...
[9 times]


====== Astro Scan Trace ======
start tracing scan chain backward ...
WARNING : Scan trace did not find the specified start port
WARNING : Scan Trace stopped at port SI, cell instance ac97_top/u120/we1_reg
INFO: creating new scan chain group <ScanGroup_ac97_top/u120/we1_reg_Q>
Traced scan chain has 481 edges
=== END Astro Scan Trace ===

Scan Trace was successful.

Astro报了两个WARNING,不知道为什么找不到指定的开始端口?axgScanChainOptim是可以执行的
请问可否忽略这两个WARNING

请大家帮忙看看,谢谢!

怎么没有人回答呢 ?自己顶一下

你可以用scandef去尝试一下

扫描链的起点应该定义在pad的末端

wo ye pengdao 我也碰到同样问题
而且在palce之后,optimazation时,无法完成,信息如下:
ERR:require eaxctly one input and output pin on each scan edge.

学习。

学习了。

谢谢!

astro年代重来没用过scan reorder成功过,总是有些问题,
不知道了,换icc 读scan def吧,

Copyright © 2017-2020 微波EDA网 版权所有

网站地图