微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 信号完整性分析 > 信号完整性分析讨论 > 请各位大侠帮我看一下这个ibis模型怎么了

请各位大侠帮我看一下这个ibis模型怎么了

时间:10-02 整理:3721RD 点击:
请各位大侠帮我看一下这个ibis模型怎么了,这是我从TI官网上下载的,在编译的时候报错:
ERROR - Model Model67: The [Rising Waveform]
      with [R_fixture]=50 Ohms and [V_fixture]=0V
      has TYP column DC endpoints of  0.00V and  1.19v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.00V and  0.98V),
      a difference of  0.00% and 21.94%, respectively.
ERROR - Model Model67: The [Falling Waveform]
      with [R_fixture]=50 Ohms and [V_fixture]=1.8V
      has TYP column DC endpoints of  0.63V and  1.80v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.88V and  1.80V),
      a difference of 27.06% and  0.00%, respectively.
WARNING - Model Model67 Pulldown Minimum data is non-monotonic
WARNING - Model Model67 Pullup Maximum data is non-monotonic
ERROR - Model Model67: The [Rising Waveform]
      with [R_fixture]=50 Ohms and [V_fixture_max]=0V
      has MAX column DC endpoints of  0.00V and  1.38v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.00V and  1.15V),
      a difference of  0.00% and 20.19%, respectively.
ERROR - Model Model67: The [Falling Waveform]
      with [R_fixture]=50 Ohms and [V_fixture_max]=1.89V
      has MAX column DC endpoints of  0.53V and  1.89v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.84V and  1.89V),
      a difference of 29.38% and  0.00%, respectively.
哪位大侠知道的帮帮忙啊,不知道的也帮我分析分析吧。
我这有一段解释:This happens because the function acdc_VI_Given_VIC_VR() in acdc.c improperly
reports the I-V/V-t intersection whenever it lies above the highest voltage in
the I-V characteristic.  This defect is likely to show itself in models lacking
clamp tables and in which either the [Pullup] or [Pulldown] table does not cover
the range from -Vcc to 2*Vcc.  Any open drain or open source model which lacks
clamp tables is likely to meet these conditions because it is likely to lack
either the [Pullup] or [Pulldown] table.  In this test case, IBISCHK generates
error messages only for the MIN data because the highest voltage in the high-
state I-V characteristic for the minimum corner lies below the 1.8 V V-T
operating voltage.
但是缺少该怎么做啊

学习了,非常感谢

可能是VI曲线不单调,那Visual IBIS软件看下IBIS模型的VI数据,

我也想知道,大侠们赶紧来帮着解决一下啊。

谢谢小编的分享

谢谢了  学习学习

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top