重新导入网络表时出错
修改board封装时我是这样的,先改完ORCAD里元件指定的封装,然后重新生成网络表,再导入PCB,但出现以下错误:
------ Oversights/Warnings/Errors ------
------ Library Paths ------
MODULEPATH = .
C:/OrCAD/OrCAD_16.0/share/local/pcb/modules
PSMPATH = .
symbols
..
../symbols
D:\ORCAD_DATA\LIB\SYMBOL\
PADPATH = .
symbols
..
../symbols
C:\OrCAD\OrCAD_16.0\share\pcb\pcb_lib\symbols\
C:\OrCAD\OrCAD_16.0\share\local\pcb\padstacks\
D:\OrCAD_Data\LIB\PAD\
#1 ERROR(SPMHNI-235): Error detected saving design.
ERROR(SPMHNI-234): Cannot write drawing, '#Taaaaaa02596.tmp' out to the directory: 'Database has a non-recoverable corruption. Contact Cadence customer support.'.
#2 Run stopped because errors were detected
我查看place/manually 发现board有的元件在这个菜单里消失了,不知道什么问题呢?请教各位了
dbdoctor一下PCB文件,是不是DATABASE 出问题了?
谢谢你,果然用DB DOCTOR CHECK 一下就可以了,重新导入网络表更新PCB时,很容易出现这个错误,难以避免。