请教大家个IBIS模型的问题,谢谢
现在在做仿真
DM642共有548个管脚
在TI网站上面下载的DM642的模型,里面只定义了277个,
在转化为DML模型后用Cadence作仿真时候加载模型的时候弹出这样的错误
Allegro PCB SI Board L 15.700000 p007 (v15-7-42E)
(c) Copyright 2004 Cadence Design Systems, Inc.
DesignLink : There is no active DesignLink.
Date : Nov 12 21:09:43 2009
******************************************************************************
INFO >> The victim net(s) checked are :
DM642-3_PADS +1_4V
******************************************************************************
INFO >> Geometry window = 10mil
******************************************************************************
INFO >> No neighbor nets were found.
******************************************************************************
ERROR >> Discrete component pin(s) with wrong PINUSE property:
Pin Component Pin Use Signal Model Design
--- --------- ------- ------------ ------
C1 U1- BI DM642_GDK DM642-3_PADS
E1 U1- BI DM642_GDK DM642-3_PADS
F1 U1- BI DM642_GDK DM642-3_PADS
G1 U1- BI DM642_GDK DM642-3_PADS
J1 U1- BI DM642_GDK DM642-3_PADS
K1 U1- BI DM642_GDK DM642-3_PADS
M1 U1- BI DM642_GDK DM642-3_PADS
N1 U1- BI DM642_GDK DM642-3_PADS
P1 U1- BI DM642_GDK DM642-3_PADS
R1 U1- BI DM642_GDK DM642-3_PADS
U1 U1- BI DM642_GDK DM642-3_PADS
V1 U1- BI DM642_GDK DM642-3_PADS
Y1 U1- BI DM642_GDK DM642-3_PADS
AA1 U1- BI DM642_GDK DM642-3_PADS
AC1 U1- IN DM642_GDK DM642-3_PADS
AD1 U1- BI DM642_GDK DM642-3_PADS
E2 U1- IN DM642_GDK DM642-3_PADS
F2 U1- BI DM642_GDK DM642-3_PADS
G2 U1- BI DM642_GDK DM642-3_PADS
请问这个问题该如何解决呀?
谢谢各位赐教
我是菜鸟,请各位多多帮忙
谢谢
按理说TI给的模型应该不会有问题呀?
那是哪里出问题了呀
搞不懂,导师逼的急
麻烦大家了
谢谢
这个事模型打开后这样:
|
[Component] DM642_GDK
[Manufacturer] Texas Instruments
[Package]
|Variable Typ Min Max
R_pkg 0.12581866 0.0708 0.1927
L_pkg 2.32E-09 1.26E-09 3.57E-09
C_pkg 1.14E-12 6.40E-13 1.77E-12
|
[Pin] signal_name model_name R_pin L_pin C_pin
C1 PCLK BPCI66T 0.1647 2.94E-09 1.24E-12
B4 NMI IT33THYPD 0.1574 2.92E-09 1.37E-12
A4 TINP0 IT33THYPD 0.1714 3.17E-09 1.50E-12
C5 TOUT0 BT3325CTPD 0.1355 2.49E-09 1.22E-12
B5 TOUT1 BT3325CTPU 0.1504 2.77E-09 1.35E-12
A5 TINP1 IT33THYPD 0.1652 3.05E-09 1.47E-12
D6 CLKOUT4 BT3315DTHYPU 0.1173 2.16E-09 1.06E-12
C6 CLKOUT6 BT3315DTHYPU 0.1352 2.50E-09 1.19E-12
C7 VP2CTL2 BT3325CTHYPD 0.1341 2.47E-09 1.19E-12
打开后有30个警告:
WARNING (line 6846) - GND Clamp Typical data is non-monotonic
WARNING (line 7520) - GND Clamp Maximum data is non-monotonic
WARNING (line 7521) - GND Clamp Typical data is non-monotonic
WARNING (line 7544) - GND Clamp Minimum data is non-monotonic
WARNING (line 7586) - POWER Clamp Maximum data is non-monotonic
WARNING (line 7766) - GND Clamp Maximum data is non-monotonic
WARNING (line 7768) - GND Clamp Typical data is non-monotonic
WARNING (line 7934) - POWER Clamp Maximum data is non-monotonic
Errors : 0
Warnings: 30
我错在哪里了呢?
俺也想知道商家提供的IBIS模型中Pin和实际元件的引脚名字不同,且数量不同时,如何处理?
pin脚不同这问题好解决,只要找到与你想要的管脚同样类型的就可以拿来进行仿真了。
lz 你有dm642的模型?我也想用,但是找不到
数量不同可以忽略
"ERROR >> Discrete component pin(s) with wrong PINUSE property"
根据这条信息,应该是器件属性错设成了discrete, 改成IC试试
应该是DISCRETE分立元件的属性设置错误了
在你的pcb版图中讲pin的map提出来,贴到你的ibis model中,只需将所要仿真的pin model补上,保存后再转成dml模型再试试