求救!!关于华为设备掉话
时间:03-26
整理:3721RD
点击:
如题。
最近一直有个基站,其硬件与干扰指标一直正常,但是掉话率一直较高,主要掉话原因为M3030H:TCH掉话次数(上行接收质量)(无)与M3030K:TCH掉话次数(其它)(无),求各位大侠给予小弟解决方式。
最近一直有个基站,其硬件与干扰指标一直正常,但是掉话率一直较高,主要掉话原因为M3030H:TCH掉话次数(上行接收质量)(无)与M3030K:TCH掉话次数(其它)(无),求各位大侠给予小弟解决方式。
M3030B:TCH掉话次数(上行接收电平)(无) | M3030C:TCH掉话次数(下行接收电平)(无) | M3030D:TCH掉话次数(上下行接收电平)(无) | M3030E:TCH掉话次数(上行FER)(无) | M3030F:TCH掉话次数(下行FER)(无) | M3030G:TCH掉话次数(上下行FER)(无) | M3030H:TCH掉话次数(上行接收质量)(无) | M3030I:TCH掉话次数(下行接收质量)(无) | M3030J:TCH掉话次数(上下行接收质量)(无) | M3030K:TCH掉话次数(其它)(无) |
2 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 |
0 | 1 | 0 | 0 | 0 | 0 | 2 | 0 | 0 | 0 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 |
1 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 1 |
1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 3 |
0 | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 4 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 0 | 0 |
1 | 0 | 0 | 0 | 0 | 0 | 5 | 2 | 0 | 9 |
0 | 1 | 0 | 0 | 0 | 0 | 5 | 2 | 2 | 5 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 5 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 |
1排查载频单板及天线,载频连线是否故障(去下话务看一下是否集中在某个载频,如果是更换载频或者先把该载频数据删啦看下情况),
2传输是否有误码,传输是否有接触不良(查看下占用得到不),
4是否有干扰,再检查一下基站数据是否配置错误。
5看看是否存在拥塞情况;
6看看是否是切换导致的掉话,如果是的话,检查下目标小区的相关情况;
7看一下是否是主B频点是否有问题,改下频点位置;
通话过程中高好电平质差掉话,检查下干扰和隐性故障
从指标中看到该小区掉话均为质量差引起,检查下该小区是否覆盖过远引起质差导致,是否有干扰,再检查一下基站数据是否配置错误。看下无线链路异常时的上下行电平是否弱,是的话调整下MS接入门限。
干扰