THERMAL RELIEF ERRORS REPORT -- X1-V-4S-M-V1.0.pcb -- Mon May 16 10:55:51 2011
Drilled pads with Nondrilled pads with
less than 100% thermal extensions less than 25% thermal extensions
Report of Thermal Spokes Generator.
On Top:
J3.7 (3385, -1340) # = 0
U2.7 (2380, 340) # = 0
U8.7 (3630, 350) # = 0
J3.15 (2985, -1340) # = 0
J1.9 (2989, -1625) # = 2
J1.11 (2889, -1625) # = 1
U5.17 (1965, 237) # = 0
J1.13 (2789, -1625) # = 0
J1.15 (2689, -1625) # = 0
J1.7 (3089, -1625) # = 2
U11.17 (3205, 232) # = 0
U11.7 (3080, 345) # = 0
J3.13 (3085, -1340) # = 0
J3.11 (3185, -1340) # = 0
U9.65 (3542.36, -731.22) # = 2
U3.65 (2237.36, -731.22) # = 2
U2.17 (2505, 227) # = 0
U8.17 (3755, 237) # = 0
U9.41 (3552.2, -967.44) # = 0
U9.38 (3493.15, -967.44) # = 0
U9.56 (3778.58, -741.06) # = 0
U9.25 (3306.14, -741.06) # = 0
U3.56 (2473.58, -741.06) # = 0
U3.41 (2247.2, -967.44) # = 0
U3.38 (2188.15, -967.44) # = 0
U3.25 (2001.14, -741.06) # = 0
U5.7 (1840, 350) # = 0
J3.9 (3285, -1340) # = 0
Total Drilled pads: 16 Total Nondrilled pads: 12
a: 覆铜时有下面的坐标的管脚应该连接而没连接,或者只连接一个。考虑单线引出。不过应根据实际情况解决。
b:这是thermals下的drilled thermals和non-drilled thermals的min.spoke个数小于您设定的数,请把drilled thermals和non-drilled thermals的设置变为flood over就可。
c:列出的是网络相同应该覆铜的但没有覆铜或者焊盘引出线少于Thermals中设置的参数。焊盘没覆铜可能是因为安全距离过大,可以添加走线;Thermals中Min.Spoke设置成1即可。
d:这个应该是焊盘覆铜没超过50%吧!
回复 jimmy 的帖子
jimmy 能在详细解释下么?a、b、c、d指的是?
1: 覆铜时有下面的坐标的管脚应该连接而没连接,或者只连接一个。考虑单线引出。不过应根据实际情况解决。
2:这是thermals下的drilled thermals和non-drilled thermals的min.spoke个数小于您设定的数,请把drilled thermals和non-drilled thermals的设置变为flood over就可。
3:列出的是网络相同应该覆铜的但没有覆铜或者焊盘引出线少于Thermals中设置的参数。焊盘没覆铜可能是因为安全距离过大,可以添加走线;Thermals中Min.Spoke设置成1即可。
4:这个应该是焊盘覆铜没超过50%吧!
回复 jimmy 的帖子
哈哈 多谢 明白了 小编真是热心啊!以后会常请教的!
原来这样,收藏
还有这回事吗,我都从来都没有去理会他呢,照样出图,好像也没有问题呀?