VCO Varactor Bank Control Logic Noise
时间:04-07
整理:3721RD
点击:
Hi all,
Has anyone ever encounter the problem that huge amount of noise brought by varactor bank control logic? I tried to switch on/off the AMOS varactor bank by changing the S/D node voltage between 0 and Vdd directly. So the control logic is directly connect to varactor S/D node, not switch is used. The logic worsens my phase noise by 5dBc.
Is there any way to solve this problem?
Thanks a lot.
Yi.
Has anyone ever encounter the problem that huge amount of noise brought by varactor bank control logic? I tried to switch on/off the AMOS varactor bank by changing the S/D node voltage between 0 and Vdd directly. So the control logic is directly connect to varactor S/D node, not switch is used. The logic worsens my phase noise by 5dBc.
Is there any way to solve this problem?
Thanks a lot.
Yi.
VCO tuning voltage is usually low-pass filtered to make VCO generate a stable frequency. In your case I would try to use a series R and parallel C for such low-pass filter.