PSS simulation in cadence
时间:04-05
整理:3721RD
点击:
Hi,
I designed subharmonic mixer in cadence. I want to find the conversion gain.
I do PSS simulation. RF=2.405Ghz LO =1.2GHz . If I set the IF freq is 5Mhz as a beat frequency, PSS is stopped at 2nd running. Error occurs.
If I set the beat frequency as automatic, It is worked well.
What is the reason for that?
For subharmonic mixer, How can I give the frequencies?
Please help me . Urgent.
I designed subharmonic mixer in cadence. I want to find the conversion gain.
I do PSS simulation. RF=2.405Ghz LO =1.2GHz . If I set the IF freq is 5Mhz as a beat frequency, PSS is stopped at 2nd running. Error occurs.
If I set the beat frequency as automatic, It is worked well.
What is the reason for that?
For subharmonic mixer, How can I give the frequencies?
Please help me . Urgent.
It might be because of harmonic numbers..
N=2405/5=481 harmonics...( at least)
If you consider 2nd,3rd,4th etc. harmonics of the carriers, this will be huge number of harmonics.
I suggest you to use automatic beat frequency.