Probe in microstrip line
Has somebody can help me in the design ... I count on you ... thank you in advance.
You did not assign Radiation boundary to the outer faces of the air box. After assigning Rad Boundary, you will notice few warnings that Radiation boundary is intersecting Finite Cond boundary. So, you need to re-prioritize the boundaries (See HFSS Help).
Finally, you are plotting Mag E / Surface J for the dielectric object. Instead select the signal path and plot. Change the scale to Log instead of Linear for better visualization.
Hello, thank you very much for answering me, unfortunately the problem always present; very bad Sparameters (S11>-10dB). According to my knowledge the probe must ensure the continuity between the two microstrip lines then the S-parameters must be similar to a single microstrip (at least behaves in the same way as to this one). I think that the transition microstrip / probe does not work properly there is certainly a trick that escapes to me ...
You would like to give me other solutions .... thanks in advance.