ibis 模型中i/o的cref,Rref是如何定义和使用的?
问题如题!高手指点,为什么有的用20pf,50欧姆,有的用20pf,1M?是否在ibis中,这些参数本身并没有作用,只是用来指导客户在板级仿真中使用,但是在具体板级仿真中这些参数似乎有没有什么,至少到目前为止,我还没有发现。另外,在测量rising waveform,和falll waveform中,大多module只是给出Rfixture,而没有Cfixture,这个也没有想太清楚,个人理解:这些曲线是用来表征pin本身的上升,下降曲线,而没有考虑实际负载情况。
高手们怎么还没出现?
The Cref and Rref subparameters correspond to the test load that the semiconductor vendor uses when specifying the propagation delay and/or output switching time of the model.
Test fixtures with R_fixture and V_fixture,V_fixture_min, and V_fixture_max only are strongly encouraged ,because they provide the BEST set of data needed to produce the best model for simulation. C_fixture and L_fixture can be used to produce waveforms which describe the typical test case setups for reference.