在其他地方装过的的onu,换到另外一个地方,配置状态总是失败,求解决方案
时间:03-09
整理:3721RD
点击:
XinXiLu(config-if-gpon-0/1)#display ont info 2 all
------------------------------------------------------------------------------
F/S/P ONT-ID SN Control Run Config Match DBA
flag state state state type
--------------------------------------------------------------------------------------------------------------
0/ 1/2 0 4857544323993707 active up normal match SR
0/ 1/2 1 485754434BF5A90A active up normal match SR
0/ 1/2 2 485754434BF5A10A active up fail match SR
0/ 1/2 3 485754434F64350A active up fail match SR
--------------------------------------------------------------------------------------------------------------
In port 2, the total of ONTs are: 4
------------------------------------------------------------------------------
F/S/P ONT-ID SN Control Run Config Match DBA
flag state state state type
--------------------------------------------------------------------------------------------------------------
0/ 1/2 0 4857544323993707 active up normal match SR
0/ 1/2 1 485754434BF5A90A active up normal match SR
0/ 1/2 2 485754434BF5A10A active up fail match SR
0/ 1/2 3 485754434F64350A active up fail match SR
--------------------------------------------------------------------------------------------------------------
In port 2, the total of ONTs are: 4
先清除数据,重新配
onu??什么东西啊?
先恢复到出厂设置 ,再进行配置
线路模板不对吧
是不是旧的SN没去授权 出现标识冲突了
原来数据没清除,新数据下发不下去!
楼上正解。