微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > PCB设计问答 > PCB设计学习讨论 > allegro 交换管脚后回标原理

allegro 交换管脚后回标原理

时间:10-02 整理:3721RD 点击:
allegro中交换管脚后,在 capture 中 back annotate后失败,提示如下。请高手指点
swp.log文件error信息:#549 ERROR(SPCODD-549): No physical part found for COMP_DEVICE_TYPE=XC3S400_1_PQFP-208_XC3S400-4PQ2, regenerate the netlist to sync with Allegro board.
              ERROR(SPCODD-516): Line Number: 4
#549 ERROR(SPCODD-549): No physical part found for COMP_DEVICE_TYPE=XC3S400_1_PQFP-208_XC3S400-4PQ2, regenerate the netlist to sync with Allegro board.
              ERROR(SPCODD-516): Line Number: 5
#549 ERROR(SPCODD-549): No physical part found for COMP_DEVICE_TYPE=XC3S400_1_PQFP-208_XC3S400-4PQ2, regenerate the netlist to sync with Allegro board.
              ERROR(SPCODD-516): Line Number: 6
#549 ERROR(SPCODD-549): No physical part found for COMP_DEVICE_TYPE=XC3S400_1_PQFP-208_XC3S400-4PQ2, regenerate the netlist to sync with Allegro board.
              ERROR(SPCODD-516): Line Number: 7
#549 ERROR(SPCODD-549): No physical part found for COMP_DEVICE_TYPE=XC3S400_1_PQFP-208_XC3S400-4PQ2, regenerate the netlist to sync with Allegro board.
              ERROR(SPCODD-516): Line Number: 8

ScreenCapture_20150804_155422.jpg

1.实际操作中需要先点击"Rename all components" 然后点击attach prpoerty,components.."去选择需要编号的器件,一般只只对R,L,C,进入器件属性编辑界面,添加“Auto_Rename"属性。
2.点击more..1 v4 z" s; i0 n% ?+ |
3. 进入more后,refdes prefix默认是*,必须先删除,填写当前对应的R,L,C.其他可以不管- n# {' I, \: H. f
4.点击close, 再点rename.$ E/ I8 _+ S0 a3 ~! ]
5. 到SCH去反标,严格执行这个过程一般不会报错。

我也遇到了同样的问题 在画FPGA的PCB时候swap了几个pin 但是在orcad CIS中就无法回标 log也是相同的 求告知原因

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top