紧急!allegro 导入网表报错
ERROR(SPMHNI-175): Netrev error detected.ERROR(SPMHDB-195): Error processing 'MTG1': Cannot modify element; the object or a parent has the FIXED property. [help].------ Library Paths ------MODULEPATH =  .            D:/Cadence/SPB_16.6/share/local/pcb/modules PSMPATH =  D:/linshi/            .            symbols            ..            ../symbols            D:/Cadence/SPB_16.6/share/local/pcb/symbols            D:/Cadence/SPB_16.6/share/pcb/pcb_lib/symbols            D:/Cadence/SPB_16.6/share/pcb/allegrolib/symbols            D:/fzk/            D:/TX/            D:/hanpan/            D:/linshi/ PADPATH =  .            symbols            ..            ../symbols            D:/Cadence/SPB_16.6/share/local/pcb/padstacks            D:/Cadence/SPB_16.6/share/pcb/pcb_lib/symbols            D:/Cadence/SPB_16.6/share/pcb/allegrolib/symbols            D:/hanpan/ ------ Summary Statistics ------#2   Run stopped because errors were detectednetrev run on Dec 6 17:38:45 2014   DESIGN NAME : 'XM'   PACKAGING ON Sep 10 2012 04:46:09   COMPILE 'logic'   CHECK_PIN_NAMES OFF   CROSS_REFERENCE OFF   FEEDBACK OFF   INCREMENTAL OFF   INTERFACE_TYPE PHYSICAL   MAX_ERRORS 500   MERGE_MINIMUM 5   NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'   NET_NAME_LENGTH 24   OVERSIGHTS ON   REPLACE_CHECK OFF   SINGLE_NODE_NETS ON   SPLIT_MINIMUM 0   SUPPRESS   20   WARNINGS ON  2 errors detected No oversight detected No warning detectedcpu time      0:00:24elapsed time  0:00:00

表示没看懂小编的问题

高亮所有GROUP,看到GROUP后,光标移动到GROUP或者MODULE位置,右键,选择disband group. 这样之后,再导入网表,就没有问题了。