can the imaginary part of complex permittivity be negative?
时间:04-06
整理:3721RD
点击:
The complex permittivity has a real and imaginary part.
Er = Er' + i Er"
the real part is usually referred as the dielectric constant, this must be a positive value,
but the imaginary part, is it always positive as well?
it should be right?
since Q, the quality factor should be a positive value as well.
Er = Er' + i Er"
the real part is usually referred as the dielectric constant, this must be a positive value,
but the imaginary part, is it always positive as well?
it should be right?
since Q, the quality factor should be a positive value as well.
For mediums that exhibit energy loss for the signal, the imaginary permittivity is positive.
For mediums that have energy gain, imaginary permittivity is negative.