微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 微波和射频技术 > 天线设计和射频技术 > Trivially: pnoise start/stop for downconversion mixer

Trivially: pnoise start/stop for downconversion mixer

时间:04-04 整理:3721RD 点击:
I have a downconversion mixer (fc = 2.1 GHz, BW=800 Mhz, i.e. f = 1.7 ... 2.5 GHz). For the reference side band I set -1.

The absolute start/stop frequency in pnoise, would I set it to 1k ... 400M or to 1.7 G ... 2.5G?

I found documents (e.g. http://www.ece.tamu.edu/~kentesar/ELEN665/lab4.pdf) where they say the former (1k....400M). Older saved states of my own have that set too.

But now I'm confused. Shouldn't it be the latter, i.e., the exciting frequencies (and hence 1.7GHz ... 2.5GHz)?

I don't know what simulator you use.

However if you use Pnoise Analysis in Cadence Spectre, it has to be 1kHz-400MHz.

You can confirm which setting is reasonable, if you surely see simulation logfile.

Copyright © 2017-2020 微波EDA网 版权所有