Faulty Location In Coaxial Cable
How "SITEMASTER" type devices measure coaxial cable fault location? Can we find fault at low frequencies?
Regards
I'm not familiar with "Sitemaster" products but the usual principle is to use TDR (Time Domain Reflectometry). Basically, you shoot a short pulse of voltage from one end of the cable and time how long it takes to bounce back. Then, knowing the velocity factor of the cable, you can work out the distance the pulse traveled and as it is a round trip, half the calculated distance is where the fault is.
Brian.
Thanks for reply.
How fast electronic circuitry is required to measure TDR system?
Some instruments use FFT from network analyzer frequency sweep instead of actually doing time domain pulses.
What resolution/accuracy for location do you need, and what fault to do need to measure? Little difference in line impedance or massive fault like open/short?
Thanks for reply
I need distance in 5 to10 meter accuracy. Once i opened SITE Master and observed that at the input stage there was a VSWR bridge built around a ferrite-core.
The fault type is little difference in impedance.
Is it possible to do this using HF 40 MHZ frequency?
I never tried, but here are numbers for reference: My KC901S+ analyzer can do cable fault location to ~5cm resolution using frequency sweep up to 4GHz.
If we scale that by factor 100 then 5m resolution from a DC to 40MHz sweep might work.
Thanks for reply
Does it measure reflected wave ? What is the basic principle?
I need a RF bridge design is there any suitable design available?
Yes, the input data is from return loss measurement (complex S11).
For a simple bridge that works down to DC, maybe you can check out the presentation of the VNWA3 low cost network analyzer here:
https://www.youtube.com/watch?v=C94J...c#action=share
Hardware block diagram including resistive bridge at 08:00
Thanks for reply
I want to make the following design. The only thing which i dont understand is the design of directional coupler, it is built around BN43-2402.
***.qsl.net/yo4hfu/VNA_IZ1PMX.html
Either a time domain pulse is sent down the cable, and a return pulse is detected, OR a swept refelction coefficient test is done on the cable end and a fast forrier transform is performed to figure out its physical distance away
Thanks for reply.
In case of time domain pulse, what should be the pulse width and duty-cycle? Is it high a frequency modulated rf pulse?
The width is chosen for the distance resolution you want. But less than 1 nanosecond width would be nice.
It is not modulated RF...it is just a spike of voltage 1 ns wide, sent down the line.
something like this perhaps?
I would add a series capacitor at the output too
Creating the pulse isn't that difficult, but you need a really fast scope to measure the reflected signal. Really really fast.
OR a slow scope, and use Equivalent Time Sampling. Cheepo S20 impulse radars use this method.
Do you have a reference for such hardware?
I'm familiar with the sampling scope method from long ago when I used TEK sampling scope for TDR, but that also required very fast analog front end for the sampler. I'm curious to see how this is solved now, 30 years later.
the use sampling diodes with ps switching speed, a hold capacitor, an SLOW analog ramp generator, and an op amp or two.
Attached is one paper...
I will try to find some better papers tonight, but they were used starting in the 1950's. Impulse radars today use them commonly, especially the commercial cheap ones. With a nonlinear transmission line generating the pulse to drive the sampling diodes, you can catch >100 GHz signals.
if you want to get fancy, you can use an IC to do the sampling:
http://www.analog.com/media/en/techn...hmc1061lc5.pdf
With all these samplers...you have to conquer the spike noise from the sampling pulse leaking into the analog sampled output...usually done by some sort of balanced pulse driver and a ring of diodes
Thanks for reply.
For swept frequency approach what bandwidth and sweep rate is required? is it possible to use few MHZ bandwidth and very fast sweep using DDS?
Accuracy of locating the fault/reflection depends on bandwidth - more is better. "A few MHz" sounds not useful to me, as discussed above. Sweep rate doesn't matter.