微波EDA网,见证研发工程师的成长! 2025濠电姷鏁告慨鐑藉极閸涘﹥鍙忛柟缁㈠枟閸庡顭块懜闈涘缂佺嫏鍥х閻庢稒蓱鐏忣厼霉濠婂懎浜惧ǎ鍥э躬婵″爼宕熼鐐差瀴闂備礁鎲¢悷銉ф崲濮椻偓瀵鏁愭径濠勵吅闂佹寧绻傚Λ顓炍涢崟顓犵<闁绘劦鍓欓崝銈嗙箾绾绡€鐎殿喖顭烽幃銏ゅ川婵犲嫮肖闂備礁鎲¢幐鍡涘川椤旂瓔鍟呯紓鍌氬€搁崐鐑芥嚄閼搁潧鍨旀い鎾卞灩閸ㄥ倿鏌涢锝嗙闁藉啰鍠栭弻鏇熺箾閻愵剚鐝曢梺绋款儏濡繈寮诲☉姘勃闁告挆鈧Σ鍫濐渻閵堝懘鐛滈柟鍑ゆ嫹04闂傚倸鍊搁崐鎼佸磹閹间礁纾归柟闂寸绾惧綊鏌熼梻瀵割槮缁惧墽鎳撻—鍐偓锝庝簼閹癸綁鏌i鐐搭棞闁靛棙甯掗~婵嬫晲閸涱剙顥氬┑掳鍊楁慨鐑藉磻閻愮儤鍋嬮柣妯荤湽閳ь兛绶氬鎾閳╁啯鐝曢梻浣藉Г閿氭い锔诲枤缁辨棃寮撮姀鈾€鎷绘繛杈剧秬濞咃絿鏁☉銏$厱闁哄啠鍋撴繛鑼枛閻涱噣寮介褎鏅濋梺闈涚墕濞诧絿绮径濠庢富闁靛牆妫涙晶閬嶆煕鐎n剙浠遍柟顕嗙節婵$兘鍩¢崒婊冨箺闂備礁鎼ú銊╁磻濞戙垹鐒垫い鎺嗗亾婵犫偓闁秴鐒垫い鎺嶈兌閸熸煡鏌熼崙銈嗗17闂傚倸鍊搁崐鎼佸磹閹间礁纾归柟闂寸绾惧綊鏌熼梻瀵割槮缁惧墽鎳撻—鍐偓锝庝簼閹癸綁鏌i鐐搭棞闁靛棙甯掗~婵嬫晲閸涱剙顥氬┑掳鍊楁慨鐑藉磻閻愮儤鍋嬮柣妯荤湽閳ь兛绶氬鎾閳╁啯鐝栭梻渚€鈧偛鑻晶鎵磼椤曞棛鍒伴摶鏍归敐鍫燁仩妞ゆ梹娲熷娲偡閹殿喗鎲奸梺鑽ゅ枂閸庣敻骞冨鈧崺锟犲礃椤忓棴绱查梻浣虹帛閻熴垽宕戦幘缁樼厱闁靛ǹ鍎抽崺锝団偓娈垮枛椤攱淇婇幖浣哥厸闁稿本鐭花浠嬫⒒娴e懙褰掑嫉椤掑倻鐭欓柟杈惧瘜閺佸倿鏌ㄩ悤鍌涘 闂傚倸鍊搁崐鎼佸磹閹间礁纾归柟闂寸绾惧綊鏌熼梻瀵割槮缁惧墽鎳撻—鍐偓锝庝簼閹癸綁鏌i鐐搭棞闁靛棙甯掗~婵嬫晲閸涱剙顥氬┑掳鍊楁慨鐑藉磻閻愮儤鍋嬮柣妯荤湽閳ь兛绶氬鎾閻樻爠鍥ㄧ厱閻忕偛澧介悡顖氼熆鐟欏嫭绀€闁宠鍨块、娆戠磼閹惧墎绐楅梻浣告啞椤棝宕橀敐鍡欌偓娲倵楠炲灝鍔氭繛鑼█瀹曟垿骞橀懜闈涙瀭闂佸憡娲﹂崜娑㈡晬濞戙垺鈷戦柛娑樷看濞堟洖鈹戦悙璇ц含闁诡喕鍗抽、姘跺焵椤掆偓閻g兘宕奸弴銊︽櫌婵犮垼娉涢鍡椻枍鐏炶В鏀介柣妯虹仛閺嗏晛鈹戦鑺ュ唉妤犵偛锕ュ鍕箛椤掑偊绱遍梻浣筋潐瀹曟﹢顢氳閺屻劑濡堕崱鏇犵畾闂侀潧鐗嗙€氼垶宕楀畝鍕厱婵炲棗绻戦ˉ銏℃叏婵犲懏顏犵紒杈ㄥ笒铻i柤濮愬€ゅΣ顒勬⒒娴e懙褰掓晝閵堝拑鑰块梺顒€绉撮悞鍨亜閹哄秷鍏岄柛鐔哥叀閺岀喖宕欓妶鍡楊伓闂傚倸鍊搁崐鎼佸磹閹间礁纾归柟闂寸绾惧綊鏌熼梻瀵割槮缁炬儳缍婇弻锝夊箣閿濆憛鎾绘煕婵犲倹鍋ラ柡灞诲姂瀵挳鎮欏ù瀣壕闁告縿鍎虫稉宥夋煛瀹ュ骸骞楅柣鎾存礃閵囧嫰骞囬崜浣荷戠紓浣插亾闁逞屽墰缁辨帡鎮欓鈧崝銈夋煟韫囨梻绠為柛鈺冨仱楠炲鏁傞挊澶夋睏闂佽楠稿﹢杈ㄦ叏閹绢啟澶娾攽閸垻锛濇繛杈剧到閹碱偊顢撳畝鍕厱闁靛ǹ鍎抽崺锝団偓娈垮枛椤攱淇婇幖浣哥厸闁稿本鐭花浠嬫⒒娴e懙褰掑嫉椤掑倻鐭欓柟杈惧瘜閺佸倿鏌ㄩ悤鍌涘
首页 > 研发问答 > 硬件电路设计 > TI电源管理交流 > BQ27542 RA 不更新问题

BQ27542 RA 不更新问题

时间:10-02 整理:3721RD 点击:

做了 充放电 3个 循环 ,Qmax已经 更新 ,RA FLAG = FF55,为什么 不能更新 RA呢 ,以前没遇到 过这种 情况

 现在的 GG 文件如下 ,清大神指点 

Configuration JEITA Temp Hys 1 掳C
Configuration JEITA T1-T2 Chg Voltage 4400 mV
Configuration JEITA T2-T3 Chg Voltage 4400 mV
Configuration JEITA T3-T4 Chg Voltage 4400 mV
Configuration JEITA T4-T5 Chg Voltage 4400 mV
Configuration JEITA T1-T2 Chg Current 50 %
Configuration JEITA T2-T3 Chg Current 80 %
Configuration JEITA T3-T4 Chg Current 80 %
Configuration JEITA T4-T5 Chg Current 80 %
Configuration Registers Pack Configuration 2931 Flag
Configuration Registers Pack Configuration B 82 Flag
Configuration Registers Pack Configuration C 38 Flag
Configuration Registers Pack Configuration D 17 Flag
Configuration HDQ Host Interrupt Tries 3 Num
Configuration Power Flash Update OK Voltage 2300 mV
Configuration Power Sleep Current 15 mA
Configuration Power Hibernate Current 8 mA
Configuration Power Hibernate Voltage 2000 mV
Configuration Power FS Wait 0 s
Configuration Lifetime Data Lifetime Max Temp 85 掳C
Configuration Lifetime Data Lifetime Min Temp -40 掳C
Configuration Lifetime Data Lifetime Max Pack Voltage 4600 mV
Configuration Lifetime Data Lifetime Min Pack Voltage 2000 mV
Configuration Lifetime Data Lifetime Max Chg Current 32767 mA
Configuration Lifetime Data Lifetime Max Dsg Current -7735 mA
Configuration Lifetime Temp Samples LT Flash Cnt 32773 Num
Configuration Lifetime Resolution LT Temp Res 1 掳C
Configuration Lifetime Resolution LT V Res 25 mV
Configuration Lifetime Resolution LT Cur Res 100 mA
Configuration Lifetime Resolution LT Update Time 60 s
Configuration Safety OT Chg 55 掳C
Configuration Safety OT Chg Time 5 s
Configuration Safety OT Chg Recovery 50 掳C
Configuration Safety OT Dsg 65 掳C
Configuration Safety OT Dsg Time 5 s
Configuration Safety OT Dsg Recovery 60 掳C
Configuration Manufacturer Data Pack Lot Code 0 Hex
Configuration Manufacturer Data PCB Lot Code 0 Hex
Configuration Manufacturer Data Firmware Version 0 Hex
Configuration Manufacturer Data Hardware Revision 0 Hex
Configuration Manufacturer Data Cell Revision 0 Hex
Configuration Manufacturer Data DF Config Version 0 Hex
Configuration Integrity Data All DF Checksum 0 Hex
Configuration Integrity Data Static Chem DF Checksum 7d5c Hex
Configuration Integrity Data Static DF Checksum 0 Hex
Configuration Data Design Voltage 3850 mV
Configuration Data Cycle Count 2 Num
Configuration Data CC Threshold 3420 mAh
Configuration Data Design Capacity 3800 mAh
Configuration Data Design Energy 14440 mWh
Configuration Data SOH Load I -400 mA
Configuration Data TDD SOH Percent 80 %
Configuration Data ISD Current 10 hourrate
Configuration Data ISD I Filter 127 Num
Configuration Data Min ISD Time 7 hour
Configuration Data Design Energy Scale 1 Num
Configuration Discharge SOC1 Set Threshold 380 mAh
Configuration Discharge SOC1 Clear Threshold 450 mAh
Configuration Discharge SOCF Set Threshold 46 mAh
Configuration Discharge SOCF Clear Threshold 69 mAh
Configuration Discharge BL Set Volt Threshold 2500 mV
Configuration Discharge BL Set Volt Time 2 s
Configuration Discharge BL Clear Volt Threshold 2600 mV
Configuration Discharge BH Set Volt Threshold 4500 mV
Configuration Discharge BH Volt Time 2 s
Configuration Discharge BH Clear Volt Threshold 4400 mV
Gas Gauging Current Thresholds Dsg Current Threshold 60 mA
Gas Gauging Current Thresholds Chg Current Threshold 75 mA
Gas Gauging Current Thresholds Quit Current 40 mA
Gas Gauging Current Thresholds Dsg Relax Time 60 s
Gas Gauging Current Thresholds Chg Relax Time 60 s
Gas Gauging Current Thresholds Max IR Correct 400 mV
Gas Gauging State Qmax Cell 0 3931 mAh
Gas Gauging State Update Status 5 Hex
Gas Gauging State V at Chg Term 4385 mV
Gas Gauging State Avg I Last Run -3000 mA
Gas Gauging State Avg P Last Run -1131 pwr
Gas Gauging State Delta Voltage 2 mV
Gas Gauging State T Rise 50 Num
Gas Gauging State T Time Constant 1000 Num
Gas Gauging IT Cfg Load Select 1 Num
Gas Gauging IT Cfg Load Mode 1 Num
Gas Gauging IT Cfg Max Res Factor 15 Num
Gas Gauging IT Cfg Min Res Factor 5 Num
Gas Gauging IT Cfg Ra Filter 800 Num
Gas Gauging IT Cfg Res V Drop 50 mV
Gas Gauging IT Cfg Fast Qmax Start DOD % 92 %
Gas Gauging IT Cfg Fast Qmax End DOD % 96 %
Gas Gauging IT Cfg Fast Qmax Start Volt Delta 200 mV
Gas Gauging IT Cfg Fast Qmax Current Threshold 4 hourrate
Gas Gauging IT Cfg Qmax Capacity Err 1.5 %
Gas Gauging IT Cfg Max Qmax Change 30 %
Gas Gauging IT Cfg Terminate Voltage 3400 mV
Gas Gauging IT Cfg Term V Delta 200 mV
Gas Gauging IT Cfg ResRelax Time 500 s
Gas Gauging IT Cfg User Rate-mA 0 mA
Gas Gauging IT Cfg User Rate-Pwr 0 pwr
Gas Gauging IT Cfg Reserve Cap-mAh 0 mAh
Gas Gauging IT Cfg Reserve Energy 0 egy
Gas Gauging IT Cfg Max DeltaV 200 mV
Gas Gauging IT Cfg Min DeltaV 0 mV
Gas Gauging IT Cfg Max Sim Rate 1 hourrate
Gas Gauging IT Cfg Min Sim Rate 20 hourrate
Gas Gauging IT Cfg Ra Max Delta 54 mOhm
Gas Gauging IT Cfg Trace Resistance 100 mOhm
Gas Gauging IT Cfg Downstream Resistance 100 mOhm
Gas Gauging IT Cfg Qmax Max Delta % 5 %
Gas Gauging IT Cfg Qmax Bound % 130 %
Gas Gauging IT Cfg DeltaV Max Delta 10 mV
Gas Gauging IT Cfg Max Res Scale 5000 Num
Gas Gauging IT Cfg Min Res Scale 200 Num
Gas Gauging IT Cfg Fast Scale Start SOC 10 %
Gas Gauging IT Cfg Fast Scale Load Select 3 Num
Gas Gauging IT Cfg Charge Hys V Shift 40 mV
Gas Gauging IT Cfg RaScl OCV Rst Temp Thresh 15 掳C
Gas Gauging IT Cfg Max Allowed Current 8500 mA
Gas Gauging IT Cfg Max Current Pulse Duration 10 s
Gas Gauging IT Cfg Max Current Interrupt Step 500 mA
Gas Gauging IT Cfg Predict Outside Temp Time 2000 s
Gas Gauging IT Cfg Termination Voltage Valid Time 2 s
Security Codes Sealed to Unsealed MSB 3672 Hex
Security Codes Sealed to Unsealed LSB 414 Hex
Security Codes Unsealed to Full MSB ffff Hex
Security Codes Unsealed to Full LSB ffff Hex
Security Codes Authen Key3 MSB 123 Hex
Security Codes Authen Key3 LSB 4567 Hex
Security Codes Authen Key2 MSB 89ab Hex
Security Codes Authen Key2 LSB cdef Hex
Security Codes Authen Key1 MSB fedc Hex
Security Codes Authen Key1 LSB ba98 Hex
Security Codes Authen Key0 MSB 7654 Hex
Security Codes Authen Key0 LSB 3210 Hex
System Data Manufacturer Info Block A 0 0 Hex
System Data Manufacturer Info Block A 1 0 Hex
System Data Manufacturer Info Block A 2 0 Hex
System Data Manufacturer Info Block A 3 0 Hex
System Data Manufacturer Info Block A 4 0 Hex
System Data Manufacturer Info Block A 5 0 Hex
System Data Manufacturer Info Block A 6 0 Hex
System Data Manufacturer Info Block A 7 0 Hex
System Data Manufacturer Info Block A 8 0 Hex
System Data Manufacturer Info Block A 9 0 Hex
System Data Manufacturer Info Block A 10 0 Hex
System Data Manufacturer Info Block A 11 0 Hex
System Data Manufacturer Info Block A 12 0 Hex
System Data Manufacturer Info Block A 13 0 Hex
System Data Manufacturer Info Block A 14 0 Hex
System Data Manufacturer Info Block A 15 0 Hex
System Data Manufacturer Info Block A 16 0 Hex
System Data Manufacturer Info Block A 17 0 Hex
System Data Manufacturer Info Block A 18 0 Hex
System Data Manufacturer Info Block A 19 0 Hex
System Data Manufacturer Info Block A 20 0 Hex
System Data Manufacturer Info Block A 21 0 Hex
System Data Manufacturer Info Block A 22 0 Hex
System Data Manufacturer Info Block A 23 0 Hex
System Data Manufacturer Info Block A 24 0 Hex
System Data Manufacturer Info Block A 25 0 Hex
System Data Manufacturer Info Block A 26 0 Hex
System Data Manufacturer Info Block A 27 0 Hex
System Data Manufacturer Info Block A 28 0 Hex
System Data Manufacturer Info Block A 29 0 Hex
System Data Manufacturer Info Block A 30 0 Hex
System Data Manufacturer Info Block A 31 0 Hex
System Data Manufacturer Info Block B 0 0 Hex
System Data Manufacturer Info Block B 1 0 Hex
System Data Manufacturer Info Block B 2 0 Hex
System Data Manufacturer Info Block B 3 0 Hex
System Data Manufacturer Info Block B 4 0 Hex
System Data Manufacturer Info Block B 5 0 Hex
System Data Manufacturer Info Block B 6 0 Hex
System Data Manufacturer Info Block B 7 0 Hex
System Data Manufacturer Info Block B 8 0 Hex
System Data Manufacturer Info Block B 9 0 Hex
System Data Manufacturer Info Block B 10 0 Hex
System Data Manufacturer Info Block B 11 0 Hex
System Data Manufacturer Info Block B 12 0 Hex
System Data Manufacturer Info Block B 13 0 Hex
System Data Manufacturer Info Block B 14 0 Hex
System Data Manufacturer Info Block B 15 0 Hex
System Data Manufacturer Info Block B 16 0 Hex
System Data Manufacturer Info Block B 17 0 Hex
System Data Manufacturer Info Block B 18 0 Hex
System Data Manufacturer Info Block B 19 0 Hex
System Data Manufacturer Info Block B 20 0 Hex
System Data Manufacturer Info Block B 21 0 Hex
System Data Manufacturer Info Block B 22 0 Hex
System Data Manufacturer Info Block B 23 0 Hex
System Data Manufacturer Info Block B 24 0 Hex
System Data Manufacturer Info Block B 25 0 Hex
System Data Manufacturer Info Block B 26 0 Hex
System Data Manufacturer Info Block B 27 0 Hex
System Data Manufacturer Info Block B 28 0 Hex
System Data Manufacturer Info Block B 29 0 Hex
System Data Manufacturer Info Block B 30 0 Hex
System Data Manufacturer Info Block B 31 0 Hex
Ra Tables Ra0 Table Ra Flag ff55 -
Ra Tables Ra0 Table Ra 0 96 2^-10ohm
Ra Tables Ra0 Table Ra 1 96 2^-10ohm
Ra Tables Ra0 Table Ra 2 105 2^-10ohm
Ra Tables Ra0 Table Ra 3 126 2^-10ohm
Ra Tables Ra0 Table Ra 4 118 2^-10ohm
Ra Tables Ra0 Table Ra 5 97 2^-10ohm
Ra Tables Ra0 Table Ra 6 113 2^-10ohm
Ra Tables Ra0 Table Ra 7 97 2^-10ohm
Ra Tables Ra0 Table Ra 8 95 2^-10ohm
Ra Tables Ra0 Table Ra 9 96 2^-10ohm
Ra Tables Ra0 Table Ra 10 98 2^-10ohm
Ra Tables Ra0 Table Ra 11 105 2^-10ohm
Ra Tables Ra0 Table Ra 12 113 2^-10ohm
Ra Tables Ra0 Table Ra 13 211 2^-10ohm
Ra Tables Ra0 Table Ra 14 394 2^-10ohm
Ra Tables Ra0x Table Ra Flag ffff -
Ra Tables Ra0x Table Ra 0 96 2^-10ohm
Ra Tables Ra0x Table Ra 1 96 2^-10ohm
Ra Tables Ra0x Table Ra 2 105 2^-10ohm
Ra Tables Ra0x Table Ra 3 126 2^-10ohm
Ra Tables Ra0x Table Ra 4 118 2^-10ohm
Ra Tables Ra0x Table Ra 5 97 2^-10ohm
Ra Tables Ra0x Table Ra 6 113 2^-10ohm
Ra Tables Ra0x Table Ra 7 97 2^-10ohm
Ra Tables Ra0x Table Ra 8 95 2^-10ohm
Ra Tables Ra0x Table Ra 9 96 2^-10ohm
Ra Tables Ra0x Table Ra 10 98 2^-10ohm
Ra Tables Ra0x Table Ra 11 105 2^-10ohm
Ra Tables Ra0x Table Ra 12 113 2^-10ohm
Ra Tables Ra0x Table Ra 13 211 2^-10ohm
Ra Tables Ra0x Table Ra 14 394 2^-10ohm