微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 硬件电路设计 > TI电源管理交流 > bq7835 CEDV 之問題

bq7835 CEDV 之問題

时间:10-02 整理:3721RD 点击:

關於設定CEDV 要上交的參數關於這幾項小弟實在看不懂,請指教

• VoltageColumn = <Zero based column number for the voltage data in your data logs>
• CurrentColumn = <Zero based column number for the current data in your data logs>
• TemperatureColumn = <Zero based column number for the temperature data in your data logs>
• ElapsedTimeColumn = <Zero based column number for the elapsed time data in your data logs>
• FitMaxSOC% = <Integer ranging from 8 to 14. Typical is 12>
• FitMinSOC% = <Integer ranging from 2 to 6. Typical is 6>
• LearnSOC% = <Integer ranging from 5 to 12. Typical is 7>

就是你要告诉系统你的数据的位置,比如说电压是第几列,记住的就是列数是从0开始的。

謝謝您的回應,還有些問題請教

1.根據SLUUB45A範例如下

Excerpted Example Data Log
In this excerpt, the columns are:
elapsed time, voltage, temperature, and current.
92, 25509, 50.9, 0
96, 25504, 50.9, 0
100, 25065, 50.9, -10102
104, 25019, 51, -10104

是只需時間、電壓、溫度、電流嗎?因儲存的LOG 裡還有很多項目是要刪掉嗎?

2. 下列這3項我在我的LOG 沒找到

FitMaxSOC%=12
FitMinSOC%=6
LearnSOC%=7

 