eNB是怎么告诉UE,PDSCH中的码字数是1还是2的?我在DCI format里面没有找到对应的字段
时间:11-23
整理:3721RD
点击:
查了一下DCI format的各个字段,
以format 2为例:有如下字段与 码字有关
- Transport block to codeword swap flag – 1 bit %是否交换码字映射
% 码字1的信息
In addition, for transport block 1:
- Modulation and coding scheme – 5 bits as defined in section 7.1.7 of [3]
- New data indicator – 1 bit
- Redundancy version – 2 bits
% 码字2的信息
In addition, for transport block 2:
- Modulation and coding scheme – 5 bits as defined in section 7.1.7 of [3]
- New data indicator – 1 bit
- Redundancy version – 2 bits
但UE是怎么能够知道enable 了几个码字呢?
如果只enable了一个码字,另一个码字对应的MCS,NDI,RV字段还要吗?
以format 2为例:有如下字段与 码字有关
- Transport block to codeword swap flag – 1 bit %是否交换码字映射
% 码字1的信息
In addition, for transport block 1:
- Modulation and coding scheme – 5 bits as defined in section 7.1.7 of [3]
- New data indicator – 1 bit
- Redundancy version – 2 bits
% 码字2的信息
In addition, for transport block 2:
- Modulation and coding scheme – 5 bits as defined in section 7.1.7 of [3]
- New data indicator – 1 bit
- Redundancy version – 2 bits
但UE是怎么能够知道enable 了几个码字呢?
如果只enable了一个码字,另一个码字对应的MCS,NDI,RV字段还要吗?
根据传输模式就可以知道了,终端还要自己测量空间矩阵秩
不是这样吧,也可以是单码字映射为很多层的,然后用spatial multiplexing的吧
下行DCI信息里有吧你看看格式2A
没有,都看过了,DCI format 2A和2差不多
比如 layer=2,可以是单码字也可以是双码字,UE是怎么知道的呢?也就是eNB层映射的方式是怎么传递到UE的?
终端根据DCI2/2A/2B里每个传输块对应的Imcs和RVidx来判断哪个传输块使能,进而确定有几个码字传输。如果传输块对应的Imcs=0且RVidx=1,则该传输块不使能。
多谢楼上的