Impedance of Z(1,1) is not 50 ohm in HFSS
Looking at your screenshot, I suspect that you have a metal object in parallel to your lumped port.
I'm not an HFSS user, but in all my EM tools a lumped port is between the metals, and looks like a port (not like a metal).
make sure you converge for very low deltas. better even look at the variation of z11 rather than S. something like delta s of 0.002 may be better for inductor. if results are far off, something is wrong with geometry..
Hi.. thanks for your prompt response.
Hi Volker.. thanks for your valuable suggestion. I have defined the port between terminals using rectangular sheet. The data table shows some non-zero values. Let me check with that values.
Looks much better, and imag{Z} scales with frequency as expected. I think you've solved your issue now.
Issue fixed. Inductance value is around 637nH. Thank you.