微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 微波和射频技术 > RFIC设计学习交流 > 请教calibre后仿真问题

请教calibre后仿真问题

时间:10-02 整理:3721RD 点击:
calibre提取参数后用ADE进行仿真,出现如下两个问题:
Error found by spectre during initial setup.
ERROR (CMI-2440):I17.M0:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M0.phvstat' group.
ERROR (CMI-2440):I17.M3:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M3.phvstat' group.
请各位大侠帮帮解答啊。

自己顶起

calibre提取参数后用ADE进行仿真,出现如下两个问题:
Error found by spectre during initial setup.
ERROR (CMI-2440):I17.M0:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M0.phvstat' group.
ERROR (CMI-2440):I17.M3:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M3.phvstat' group.
请各位大侠帮帮解答啊。

英文不是写的很清楚吗?

请问这个怎么解决的?
小编

這問題怎麼解決?

我遇过一次,跟工艺缩放有关
Change scale value 0.9 -> 1
HSPICE : Analog options -> Model analysis options -> general Options
Spectre : Options -> analog -> Component tab

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top