请教calibre后仿真问题
时间:10-02
整理:3721RD
点击:
calibre提取参数后用ADE进行仿真,出现如下两个问题:
Error found by spectre during initial setup.
ERROR (CMI-2440):I17.M0:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M0.phvstat' group.
ERROR (CMI-2440):I17.M3:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M3.phvstat' group.
请各位大侠帮帮解答啊。
Error found by spectre during initial setup.
ERROR (CMI-2440):I17.M0:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M0.phvstat' group.
ERROR (CMI-2440):I17.M3:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M3.phvstat' group.
请各位大侠帮帮解答啊。
自己顶起
calibre提取参数后用ADE进行仿真,出现如下两个问题:
Error found by spectre during initial setup.
ERROR (CMI-2440):I17.M0:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M0.phvstat' group.
ERROR (CMI-2440):I17.M3:Instance length or width does not fit the given lmax-lmin or wmax-wmin range for any model in the 'I17.M3.phvstat' group.
请各位大侠帮帮解答啊。
英文不是写的很清楚吗?
请问这个怎么解决的?
小编
這問題怎麼解決?
我遇过一次,跟工艺缩放有关
Change scale value 0.9 -> 1
HSPICE : Analog options -> Model analysis options -> general Options
Spectre : Options -> analog -> Component tab