LMK04803B的dbc/Hz
我用 信号分析仪 测量输出时钟,测得的数据,其单位是dbm。
LMK04803的DATASHEET上,给出的单位是dbc/Hz。
dbm与dbc/Hz之间,是如何换算的呢?
Hi James,
The dBm and dBc are completely different so there is no 'conversion' between the two.
dBm - indicates the power measurement relative to 1 milliwatt. 0 dBm means no change from 1 mW, i.e. a power of exactly 1 mW. 3 dBm means 3 dB greater than 0 dBm. dBm is the relative difference to a fixed reference power of 1 mW.
dBc — indicates the power relative to the power of the main carrier frequency; typically used to describe spurs, noise, channel crosstalk, and intermodal signals which may interfere with the carrier. dBc is the relative difference to an arbitrary reference power level, the power level of the carrier frequency.
假设:Offset=0,-10dbm
Offset=2KHz,-60dbm,
那么:Offset=2KHz的时候, 是多少 dbc/Hz 呢?
Hi James,
-50dBc/Hz
我是用LMK04803B生成400MHz时钟,那么如何评估400MHz时钟的质量呢?
建议还是用相噪分析仪测试一下吧
我现在用的是Agilent的EXA N9010A,不知道能否满足测量的要求呢?
Hi James,
用N9010测LMK04803的相噪应该能看到相噪的大概趋势,无法准确测量。
N9010的噪底比较高,无法达到LMK04803在某些频点的相噪水平,这个你可以看一下仪器的相关指标确认一下。