用CST MS仿真设置平面波后出现问题
时间:10-02
整理:3721RD
点击:
用CST MS仿真,激励源为平面波,设置完后运行出现如下错误,不知哪里有问题?谢谢!
(TLM Solver) : Error number 1122
(TLM Solver) : The equivalent surface used to capture near field behaviour must be either completely inside the excitation region, or it must be completely outside or coincident with the excitation must be completely outside or coincident with the excitation region extents.
(TLM Solver) : Error number 1122
(TLM Solver) : The equivalent surface used to capture near field behaviour must be either completely inside the excitation region, or it must be completely outside or coincident with the excitation must be completely outside or coincident with the excitation region extents.
那个edit excitation surface你有没有设置啊?有设置的话,都改回默认。
你的mesh设置,发上来看看?
edit excitation surface设置改变后还是出现同样的错误,不知道下述两个设置是什么意思。
等lantianyi解惑谢谢
那天发了个回复,没成功?
1、那个enclosing all mesh是默认的,就是所有网格参与的意思吧,反正我从来没改过这个选项,以前也听人说改了这个会报错。
2、建议你把mesh 设置的那两个0%的也改成10%试试?
把mesh设置的0%改为10%,可以运行了,多谢斑竹啊
不过问句多余的啊,小编当时设置0%的时候是为啥呢?是否有一些其他的考虑?
我是参考雷击例子的设置,它的雷击进入点和离开点方向的mesh设置为0%,其他为30%,好像激励源添加的方向就不用额外再扩充30%的边界条件了,不太明白是何原因。
本例中我想用平面波来代替远场雷电激励,把y方向的mesh改为0%就出错,改为10%就可以运行,不过还是不太明白其中的原因呐。
看了帮助文件《CST MS-workflow and solver overview》里的Mesh extents and boundary conditions的有关0%、10%等相关描述,也没怎么看明白。唉。
你这个问题应该是平面波的“激励位置”贴到了模型体,但是雷击不同,雷击的仿真边界是必须接触模型的,当然,接触的是wire之类而不是模型本体。