校准第一次老是显示501 AFC 不过
AFC之前那个CAPID校准,有没有选上?
上面的大哥 谢谢指点!我已经选上了的!
难道是小编的ini文件里面写的太偏了?
抓个配置和log来看看
应该是设置的初始值偏离较多,第一次校准不能校到限值内,需要修改
这个是INI配置文件里的;不知道对不对 ,需要怎么改呢;
[AFC control]
Initial value=4127
Slope=6.7368
[Crystal AFC control]
cap_id=25
[BB TX Parameters]
BB TX common mode voltage=-1
BB TX gain=0
BB TX calrcsel=0
APC bat low voltage=3.500000
APC bat high voltage=4.000000
APC bat low temperature=0.000000
APC bat high temperature=50.000000
Trim I=0
Trim Q=0
Offset I=-10
Offset Q=-1
Calibrated flag=1
BB TX phasesel=0
High band BB TX common mode voltage=-1
High band BB TX gain=0
High band BB TX calrcsel=0
High band Trim I=-1
High band Trim Q=2
High band Offset I=-9
High band Offset Q=-3
High band BB TX phasesel=0
[GSM900 level, ramp]
APC dc offset=128
Low APC dc offset=0
APC lowest power=5
与AFC相关的主要是这几项
[AFC control]
Initial value=4127
Slope=6.7368
[Crystal AFC control]
cap_id=25
LZ可以把已经校准通过的PCB中的这几项数据写进去
个人敢接Slope值高了一些
我们近期也出现过这种问题
CRYSTAL_DAC1=3800
CRYSTAL_DAC2=4200