关于放大器在高低温下增益平坦度恶化的问题.
most active components usually have such performance changes in different temperature. So it will be not unreasonable to have 2dB of gain flatness.
By the way, +/-1dB gain flatness is good enough for most RF systems. You need more?
要加温补电路
效果应该好点
generally, the error of gain flatness in high and low temperature should be less than 1dB, the 2dB is larger. at the prophase of design circuit, the influence of temperature should be considered.
by the way, does your match circuit use the lumped components or distribution line?
如果你高低差别很大如:-45~+80度的话,也是可以接受的啊。
要加温度补偿电路,集总元件也能做到好的平坦度。
You can test RFout return LOSS, perhaps at low temp,return loss change to worse,and affect flatness.
增益平坦度恶化还不是最重要的,由于管子的温度特性和分布参数在高低温下的变化,会导致放大器所有性能的变化以及恶化。比如增益的变化,还有NF等。所以产品都有高低温性能测试要求的。记得作军品时候是-40到+85 把。如果你的产品工作环境要求很高,一定要用温补电路。
是指摸拟温补电路吗?那是可行的,但稳补衰减器不知道是不是也行,摸拟温补电路很难做到一致,数字稳补比较好!
除了温补之外,还有名有其他的方法?
我认为小编的意思是高低温时带内不平度在变化。我认为温度补偿补偿增益还可以,如何来补带内不平度呢?我遇到过SAW引起高低温带内不平度变化的情况,很严重。
关注中.....希望高手解答,如何补偿带内不平度!
繼續調試常溫下帶内平坦度,你SPEC上低溫下帶内平坦度不會這麽差吧,問題還出在匹配上
摟主,這問題解決了嗎?解決的方法共享阿!
加一个温补电路就可以了,我遇到过这样的问题
这位朋友,你好,请问可以将您的这个电路发上来给我们参考一下吗:)谢谢了!
哥哥们你们说加温补电路就行了,可是我怎么也想不出,加温补电路如何去补偿带内不平度?高手们给个解答啊....
需要温度补偿 像高通平台上都有频率补偿和温度补偿同时起控。
1、可以调整PA的匹配元件和天线匹配 使得常温下尽量平坦
2、利用温补电路保证其他温度下 功率基本不变
加个温补吧,效果挺明显的.